High Voltage Current Transformer

Jdzx9-35 Jdzxf9-35 Indoor High Voltage Transformer Jdz (X) 9-24 (G) (Q) Jdz9

JDZX9-35 / JDZXF9-35 Indoor High Voltage Voltage Transformer (VT), 35kV Rated, Epoxy Resin Cast, Single Phase, IEC Standard for Metering & Protection.

Basic Info

Model No.1
PhaseSingle
Operation ConditionOutdoor
UsageProtection, Measurement
Winding FormMultilayer Honeycomb Type
Insulating MediumInsulating Gas
InstallationActive Type
Magnetic Circuit StructureCombined Type
Voltage Transformation PrinciplePhotoelectric Type
Primary Current100A – 5000A
Secondary Current5A.1A
Size SpecificationK-30×20
Rated Insulation VoltageAC 500V
Frequency50/60Hz
SpecificationStandard
Transport PackageStandard
TrademarkTengtai
OriginChina

Packaging & Delivery

Package Size20.00cm * 50.00cm * 60.00cm
Package Gross Weight5.000kg

An overview of theJDZ-3Q voltage transformer

Single-phase epoxy resin casting JDZ voltage transformer is indoor double coil voltage transformer. Applied to ac 50 hz in the power system for voltage, electric energy measurement and relay protection.

Types of meaning

Conditions of use

1. The altitude does not exceed 1000 m

2. The ambient temperature is not higher than + 40 ºC, no less than 5 ºC

3. The surrounding air relative humidity is not more than 85% (20 ºC)

4. This product is able to withstand the equivalent of nine on the Richter scale LieDu acceleration of 0.4 g sine wave test

5. This product can be used in the polluted environment

Introduction of the structure

This series transformer is epoxy resin casting type insulation structure, the core of fold type, core column on the suit the primary and secondary windings, the primary winding and secondary winding are concentric, around the same skeleton, the whole coil, external use epoxy resin casting forming secondary winding wire through two built-in nut on the casting body for a.x derivation. A winding lead by the two high pressure on the casting body terminal WeiOu derivation A.X

Technical parameters

typeJDZ-3(Q)JDZ-6(Q)JDZ-10(Q)
Rated voltage than V1000/100
2000/100
3000/100
6000/10010000/100
HZ frequency505050
Secondary rated output

0.2 on the Richter scale are unlikely

0.5 on the Richter scale are unlikely

Level 1

Level 3

30
50
80

30
50
80
200
30
80
150
300
Maximum output VA200400500
KV rated insulation level3.6/23/407.2/32/6012/42/75

 

typeRated voltage than VfrequencySecondary rated outputMaximum outputKV rated insulation level
0.20.50.2/0.20.5/0.5
JDZ-10(Q)10000/10050308025/2550/502X30012/42/75