Every inquiry that mentions “absolute rotary encoder” eventually hits the same fork: absolute or incremental? The two technologies answer different questions about a shaft, cost different amounts, and fail in different ways — yet most comparison content online stops at “absolute remembers position, incremental does not”, which is not enough information to specify anything. This guide covers the three decisions that actually determine the choice — position retention, reference logic, and interface — plus the resolution, speed and protection levels that finish the specification.

One disclosure before the tables: our rotary encoder range is incremental encoder products, so this article is written from the position of a supplier that sells incremental daily and specifies absolute when the application demands it. That is also the honest way to read the decision path at the end.

Quick Answer: The Three Decisions That Choose the Technology

DecisionChoose absolute whenChoose incremental whenなぜそれが重要なのか
Position retention after power lossAxis must be usable immediately after re-power, or re-homing is unsafe/expensiveMachine homes at every start anyway; power cycles are plannedDefines commissioning time and recovery behaviour
Reference / homing logicNo reference switch wanted — position is known from the code disc itselfHoming routine to a switch or mark is acceptable, even desirable for accuracyDrives hardware cost and start-up sequence
Interface and distanceSSI, BiSS C, EnDat, or parallel — controller supports it nativelyA/B/Z quadrature, line driver (RS-422), open collector — the universal defaultWrong interface means an extra converter or a controller swap

If all three rows point the same way, the decision is done. When they split — say, re-homing is acceptable but the interface must be SSI — the split row wins, because interface mismatches are the most expensive to fix late.

<img decoding=” />

How Each Technology Actually Encodes Position

アン インクリメンタルエンコーダ outputs pulses as the shaft turns. The controller counts pulses from a known reference; the count is the position. Nothing in the encoder “knows” an absolute angle — the position exists only as the controller’s accumulated count. Power loss or a glitch erases it, and the machine must re-home to a reference switch or Z-index mark to recover. The technology’s strengths follow from this simplicity: few conductors, high resolution cheaply (a 2500 PPR disc is commodity hardware), and noise immunity through differential line signals.

アン absolute encoder reads a physically coded pattern on the disc — single-turn absolute gives a unique code for every angle within one revolution; multi-turn absolute additionally counts revolutions through gearing or electronic memory. The position is read, not accumulated, so it survives power loss without batteries (for optical multi-turn) or with them (for electronic multi-turn). The costs are the coded disc, the serial interface electronics, and roughly a 2–5× price multiple over an incremental unit of the same mechanical size.

What “resolution” means in each case — they are not comparable numbers

Incremental resolution is quoted in PPR (pulses per revolution): 100, 250, 500, 1024, 2500 are the standard steps. The controller multiplies by 4 with quadrature decoding, so a 2500 PPR encoder yields 10,000 counts per revolution. Absolute resolution is quoted in bits: 12-bit single-turn = 4,096 positions per revolution, 17-bit = 131,072. Comparing “2500 PPR” with “17-bit” directly is a category error — convert both to counts per revolution before deciding which is finer.

必要性Incremental (quadrature counts)Absolute (bits)Reality check
Motor commutation / speed loop100–2500 PPR—Commutation needs U/V/W hall tracks, not just counts
Positioning to 0.1°≥ 3600 counts/rev → 1024 PPR (with ×4)≥ 12-bitEither technology reaches this cheaply
Positioning to 0.01°≥ 36,000 counts/rev → 10,000 PPR class≥ 15-bitAbsolute gets more economical here
Linear positioning on a ball screwResolution ÷ pitch × gear ratioSame, plus multi-turn if screw > 1 rev per strokeMulti-turn range must exceed the stroke’s revolutions

Position Retention and the Real Cost of Re-Homing

The reason absolute encoders exist is not elegance — it is what happens after power loss. Assess your re-homing reality with three questions:

  1. Can the axis physically home? A vertical axis under gravity, a gripper holding a workpiece, or a gantry over an obstacle cannot always be driven to a reference switch safely.
  2. What does homing cost in time? A 30-second homing cycle on a machine that starts once per shift is noise. On a machine cycling power 50 times per shift it is 25 minutes of lost production per shift.
  3. Is position safety-critical after re-power? Telescopic cranes, lifts, and medical positioning must know where they are before the first motion — not after.

If any answer is “no, expensive, or yes”, absolute encoding is justified regardless of the price multiple. If all three are benign, the incremental encoder’s simplicity is an advantage: fewer failure modes, a universal interface, and the cheapest replacement part in the cupboard. Our GOS38D incremental rotary encoder covers the standard 38 mm industrial footprint for exactly those applications.

Multi-turn absolute: the batteries question

Multi-turn absolute encoders come in two constructions. Optical/mechanical multi-turn uses a gear train inside the encoder — no battery, position survives any power interruption indefinitely, higher cost and a taller body. Electronic multi-turn uses a counter backed by a capacitor or battery — slimmer and cheaper, but the counting principle needs power maintenance: capacitors hold for days, batteries for years with a replacement schedule. Specify the construction deliberately; “multi-turn absolute” alone does not tell you which behaviour you bought.

Interfaces: Where Compatibility Is Won or Lost

InterfaceテクノロジーMax practical distanceController requirementNotes
A/B/Z quadrature + line driverIncremental~100 m (RS-422 differential)High-speed counter inputThe universal default; open-collector variants suit short runs
Push-pull / HTLIncremental~50 m24 V counter inputCommon on PLC high-speed inputs
SSIAbsolute~100 mSSI master or dedicated inputSimplest absolute interface; clock-driven, no protocol stack
BiSS CAbsolute~100 mBiSS masterHigher cycle rates, register access, parameter channel
EnDat 2.2Absolute~100 mDrive with EnDatVendor ecosystem (Heidenhain); diagnostics and parameter storage
Analog (0–10 V / 4–20 mA)Potentiometer-type / sensorShort; noise-sensitiveAnalog inputNot an encoder interface in the strict sense; included because it appears in inquiries

The interface check that saves the most pain: confirm the master side before ordering the encoder. A PLC with only high-speed counter inputs cannot read SSI without an add-on module; a servo drive configured for EnDat will not accept BiSS C. Reverse cases exist too — adding an absolute encoder to a controller that only counts quadrature is the most common dead-end we see in specification reviews.

Resolution, Speed and Protection: Completing the Specification

Shaft speed and the electrical frequency ceiling

Mechanical speed ratings (RPM) get all the attention, but incremental encoders also have an electrical ceiling: output frequency = PPR × 4 × RPM ÷ 60. A 2500 PPR encoder at 3000 RPM produces 500 kHz — above the rating of some counter inputs and cable runs. Either reduce resolution or check that the line driver and the controller input both handle the frequency with margin. Absolute serial interfaces have their own cycle-time limits (SSI clock rates), which cap position update rate rather than speed itself.

Protection grade and the environment that actually surrounds the shaft

環境Minimum ratingAdditional requirements
Clean indoor panelIP50/IP54Standard shaft seal
Machining splashes, humid workshopsIP65Radial shaft seal, corrosion-resistant housing
Washdown, outdoor, dust-ladenIP67Laser-welded housing, wide temperature elastomers
Continuous immersion / high-pressure jetsIP68/IP69KSpecial sealing systems; verify with the manufacturer, not the datasheet boilerplate

Two mechanical details decide survival more than the IP number: the shaft seal (the first thing abrasive dust attacks) and the mating tolerance of the coupling — a rigid coupling on a shaft with 0.2 mm runout loads the encoder bearing until it fails, whatever the housing is rated at. Always specify a compliant (double-diaphragm or slotted) coupling on any shaft you do not control.

Electrical and thermal margins

  • Supply voltage: 5 V (RS-422 line drivers), 10–30 V (HTL/push-pull), 24 V typical for absolute units — match the controller’s available rail, not the other way round.
  • Temperature: standard industrial −20 to +85 °C covers most; high-temperature classes (up to 120 °C) exist for motor-mounted units but cost more and shorten seal life.
  • Shaft load: axial and radial ratings in Newtons at a stated RPM — check them against your belt tension or gear mesh forces, especially on small 38 mm frames.

The Decision Path in Six Lines

<img decoding=” />

  1. Must the axis know its position after power loss without homing? Yes → absolute (single-turn, or multi-turn if the axis turns more than once across its travel).
  2. Is re-homing acceptable and safe at every start? Yes → incremental, and the choice is already finished for most machines.
  3. What interface does the master support? Match the encoder to the controller that exists, not the one you wish existed.
  4. Convert resolution to the same unit (counts/rev) before comparing PPR with bits.
  5. Check the electrical frequency ceiling at your top RPM, not just the mechanical RPM rating.
  6. Spec the seal for the shaft environment and the coupling for the shaft error — these two kill more encoders than the electronics ever do.

For the applications where the path lands on incremental — the large majority of speed loops, counting tasks and homed axes — our 38 mm and 45 mm series such as the GOS38A04 heavy-duty shaft encoder and the GOS38D carry the standard industrial option set: 100–2500 PPR, line driver or push-pull output, IP65 housings. Browse the full range in the rotary encoder category, and for the symbol and wiring conventions on drawings, encoder symbol and wiring guide.

よくある質問

Can an incremental encoder be used for absolute positioning?

Only within one power cycle, after homing. With a battery-backed counter module the count can survive power loss, but that moves the criticality from the encoder to the counter — an absolute encoder is the cleaner engineering answer when retention is required.

Is a multi-turn absolute encoder worth the cost on a ball screw axis?

If the screw rotates more than one revolution across full travel and the axis cannot re-home, yes — single-turn absolute would report the same angle at multiple physical positions. Check the multi-turn range against the screw’s total revolutions with margin.

What does 2500 PPR mean in positioning accuracy?

With quadrature ×4 decoding it is 10,000 counts per revolution, or 0.036° per count. Mechanical accuracy also depends on coupling quality, backlash and the mechanics — the encoder count is a ceiling, not a guarantee.

Why does my incremental encoder lose position after an emergency stop?

Emergency stop circuits often cut control power, which erases the accumulated count. If the machine must resume exactly where it stopped, either keep the counter powered through the stop (with a safe-speed restart procedure) or move that axis to an absolute encoder.

Which is more reliable, absolute or incremental?

Neither categorically. Incremental units have fewer components and a simpler interface; absolute units remove the homing switch and reference cycle from the failure inventory. Reliability is decided by sealing, coupling and environment far more than by the encoding principle.

Previous Post

Aircraft vs Aerospace vs Aviation Connectors: What Buyers Actually Mean

Next Post

Pendant Control Station Wiring: 2, 4, 6 and 8 Button Layouts

関連記事

+86-19730226757 Phone sales@wilmall.com E-mail Chat on WhatsApp WhatsApp