Product Overview: Introduction, Core Application, Key Features
Current transformers (CTs) are essential instrument transformers used to measure alternating current (AC) in electrical systems. They step down high primary currents to manageable secondary currents for metering and protection devices, ensuring safety and accuracy.
Core Application
Metering: Provides precise current measurement for billing and monitoring.
Protection: Supplies accurate current data for relays and circuit breakers to detect faults.
Control Systems: Interfaces with automation and monitoring equipment.
Energy Management: Supports load analysis and power quality checks.
主な特徴
特徴
説明
CT Ratio
Converts high primary current (e.g., 1000 A) to standard secondary current (5 A or 1 A).
Accuracy Class
Class 0.5 or 1.0 for metering; 5P10 or similar for protection.
Burden (VA) Rating
Rated secondary load capacity, ensuring precise output under load.
Construction Types
Window type, bar type, toroidal, and split core options for varied installation needs.
Polarity Markings
Clear P1/P2 labels to maintain correct phase relationship.
Safety Insulation
Designed to isolate high voltage primary circuits safely from measurement instruments.
Current transformers maintain system reliability by delivering accurate current scaling and ensuring safe, effective operation of meters and protection devices.
Technical Specifications & Performance Data
Understanding the technical specs of a current transformer (CT) is key to picking the right one for your needs. Here’s a breakdown covering current ratio configuration, accuracy, protection classes, and burden rating.
Current Ratio Configuration
The CT ratio defines the relationship between the primary current (input) and the secondary current (output). Common ratios include 100:5, 200:5, or custom configurations depending on your system. This ratio ensures correct scaling for metering or protection devices.
パラメータ
代表値
Primary Current
5A up to several kA
Secondary Current
Standard 5A or 1A
Ratio Range
e.g., 100:5, 200:5, 400:5
Accuracy & Metering Classes
Metering CTs must be highly accurate to ensure precise readings. Accuracy classes like 0.5 そして 1.0 indicate how closely the CT output matches the actual current. For example:
Class 0.5: Max error of 0.5% under stipulated conditions
Class 1.0: Max error of 1%
Protection Classes (Saturation Characteristics)
Protection CTs, often rated as 5P10 or 10P20, are designed to handle high fault currents without saturating too early. This means they maintain accuracy during short circuits or overloads.
5P10: Saturation point at 10 times nominal current, suitable for protection relays
10P20: For more demanding protection applications
Rated Burden (VA Rating)
The burden rating (VA rating) is the maximum load that the CT secondary can drive while maintaining accuracy. It includes wiring, meter, and relay impedance. Typical burdens range from 5VA to 30VA or higher. The rated burden ensures the CT delivers reliable output without overheating or distortion.
仕様
詳細
Rated Burden (VA)
5VA to 30VA or more
Secondary Current
1A or 5A
Accuracy Class
0.5, 1.0 (Metering)
Protection Class
5P10, 10P20
Selecting the right combination of these specs means your instrument transformer will support your application whether for metering or protection. For wiring and setup details, check out our resources on pendant control station solutions for integrated control systems.
Construction & Dimensions
Current transformers come in various designs tailored for different applications. Understanding their construction and size helps you pick the right type for your setup.
Casing Material
Plastic (Thermoplastic): Lightweight, corrosion-resistant, ideal for indoor use.
Metal (Aluminum/Stainless Steel): Durable, provides better shielding, suited for harsh industrial environments.
Composite Materials: Enhanced insulation and mechanical strength.
Mounting Options
Panel Mount: Fixed directly onto switchboards or meter panels.
Busbar Mount: Designed for easy installation on busbars in switchgear.
DIN Rail Mount: Fits standard DIN rails for compact setups.
Clamp/Split Core: Openable core for retrofit without disconnecting conductors.
Window/Aperture Size
タイプ
Aperture Size Range
申し込み
Toroidal (Ring) CT
20mm to 150mm
Cable or busbar pass-through
Bar Type CT
Fixed bar or rod
Direct conductor integration
Window Type CT
Large opening for conductor
Easy installation in busbars
Terminal Details
Screw Terminals: Common for secure connections in fixed setups.
Plug-in Connectors: Quick connect/disconnect, often found in panel-mount CTs.
Lead Wires: Pre-attached insulated wires for flexible wiring.
Choosing the right construction depends on your installation environment, space constraints, and conductor type. For example, split core CTs are perfect for retrofitting existing circuits without downtime, whereas panel-mount, sealed casing CTs offer robust performance in controlled settings.
For related accessories, consider checking the SD13 series connectors designed for secure and efficient CT wiring.
Selection Guide: Metering vs. Protection CTs
Choosing the right current transformer (CT) depends mainly on whether it’s for metering or protection purposes. Metering CTs focus on accurate measurement and monitoring of electrical current, making them essential for billing and system analysis. These typically feature a CT ratio designed to precisely scale down the primary current to a measurable secondary current, with tight accuracy classes like Class 0.5 or 1.0, ensuring minimal error over a wide range of loads. Metering CTs usually have a rated burden (VA rating) optimized for high accuracy at normal operating loads.
Protection CTs, on the other hand, are built to quickly respond to fault conditions and trigger protective relays. They are designed with protection classes such as 5P10, which indicate their ability to endure short-duration overcurrents without saturating. This makes them more robust but less focused on precision under normal load. Protection CTs, including types like split core CT or bar type CT, often deal with higher burdens and need to maintain accuracy during transient events.
When selecting, consider:
Metering CT for billing, regular monitoring, and energy management.
Protection CT for system safety, fault detection, and relay operation.
Ensure the CT polarity (P1/P2) そして window/aperture size fit your installation.
Match the burden VA rating to your equipment load.
Check compatibility with the system voltage and current levels.
For detailed options, like low voltage CT or busbar-mount window type current transformers, explore Wilmall’s range including reliable models such as the low voltage current transformers for protecting electrical energy that fit various metering and protection needs seamlessly.
Installation & Wiring Diagrams: Polarity Marking and Safety Warnings
Proper installation of current transformers (CTs) is crucial for accurate performance and safety. Always pay close attention to CT polarity markings, usually indicated as P1 and P2 on the primary side and corresponding terminals on the secondary side. Correct polarity ensures correct phase relationships and accurate readings, especially important when using multiple CTs in metering or protection schemes.
When wiring your CT, refer to clear wiring schematics to connect the secondary terminals correctly to measuring instruments or protection relays. Miswiring can lead to inaccurate current ratio readings or damage the connected devices.
Key Installation Tips:
Observe CT Polarity: Connect P1 to the source side and P2 to the load side to maintain correct phase angle.
Secure Secondary Wiring: The secondary circuit must never be open under load; always short the secondary terminals before disconnecting to avoid dangerous high voltages.
Follow Safety Guidelines: Use insulated tools and ensure the power source is de-energized before installation.
Use Proper Mounting: Depending on CT type — whether a window type current transformer or a split core CT — ensure it is mounted securely on busbars or cables.
For detailed safety and installation instructions, always consult the manufacturer’s documentation. Safe wiring practices not only protect equipment but also personnel from electrical hazards.
For further insights on sensor wiring and installation practices, explore our guides on proximity switch sensor wiring that share practical wiring tips applicable in similar industrial environments.
Why Choose Wilmall Current Transformers?
When it comes to current transformers (CTs), Wilmall stands out for several key reasons. Whether you need a toroidal current transformer, bar type CT, or a specialized split core CT, our products deliver consistent performance you can trust.
品質保証
Rigorous Testing: Each CT undergoes comprehensive testing to ensure accuracy, durability, and safety.
Durability: Built with high-grade materials that withstand industrial environments.
Reliable Accuracy: Supports classes like class 0.5 accuracy そして protection class 5P10, meeting the demands for precise metering and protection.
Standards Compliance
Wilmall current transformers comply with major international standards, including IEC and ANSI, ensuring compatibility and safety. This means you get:
Standard
ベネフィット
IEC 60044-1
Accurate metering & protection CT performance
ANSI C57.13
Industry-approved design and safety
These certifications guarantee that your instrument transformers perform reliably in your system.
Customization Options
We offer tailored solutions to fit your unique application needs:
CT Ratio: Configurable primary/secondary current ratios (e.g., 2500/5A).
Burden VA Rating: Options suitable for different load conditions.
Mounting Styles: From busbar CTs to window type current transformers made to fit your setup.
Special Features: Custom casings, aperture sizes, and terminal arrangements.
Need a CT matched to your exact requirements? Wilmall’s team is ready to help.
For detailed specs on low voltage CTs, check out our reliable BH 0.66kV 2500/5A Current Transformer for an example of our quality and customization in action.
Frequently Asked Questions (Technical FAQ)
Question
Answer
What is a CT ratio?
The CT ratio is the relationship between primary and secondary current, e.g., 1000:5 A.
What are metering and protection CTs?
Metering CTs provide accurate current measurement (Class 0.5), while protection CTs handle fault currents (Class 5P10).
What does burden (VA rating) mean?
Burden refers to the load the CT can supply on the secondary side without accuracy loss.
How to identify polarity P1 and P2?
Polarity marks P1 and P2 indicate the primary current direction and are essential for correct wiring.
What is secondary current injection?
A testing method where a known current is injected on the secondary to verify CT accuracy.
Can I use a split core CT or toroidal CT for busbar measurement?
Yes, split core and toroidal current transformers are ideal for easy installation around busbars or cables, like those found in low voltage applications. See our DSC Series Low Voltage AC Current Transformer for options.
What construction types are available?
Options include bar type, window type, and split core CTs to suit different mounting and wiring needs.
What standards do Wilmall CTs comply with?
Wilmall CTs meet international standards for accuracy, safety, and performance to ensure reliable operation.
If you have more questions about specific applications or technical details, our split core instrument transformers page offers detailed insights and product choices to match your needs.
A current transformers (CT) is a device used to safely measure alternating current in power systems by stepping a large line current down to a much smaller, manageable value in its secondary winding, while keeping the ratio proportional between primary and secondary currents for accurate calculation of the original current. This reduced current can then be sent to meters, protective relays, data loggers, or SCADA systems, which use it for monitoring, billing, and protecting connected equipment from abnormal operating conditions. This article decodes the step-down method and the principle behind how current transformers operate by deconstructing it down to fundamental parts. How Does a Current Transformers Work A Low Voltage […]
When it comes to electrical design and industrial procurement, few components are as essential as current transformers (CTs). But if you’ve ever looked at an electrical schematic filled with mysterious lines, dots, and triangles, you might have wondered — what exactly do those current transformer symbols mean? In this article, we’ll unpack the meaning behind current transformer symbols, explain how to read them in circuit diagrams, and give B2B buyers insights into selecting the right CT for their operations. Let’s turn those schematic symbols into clear, actionable understanding. What Is a Current Transformer? A High Accuracy Mini Split Core current transformer is an electrical device that measures alternating current (AC) by producing a reduced current […]
I. Product Overview & Engineering Design Introduction Solid core current transformers (CTs) are essential instrument transformers designed to provide accurate current measurement and reliable electrical protection. Featuring a robust toroidal core, these through-hole current transformers are widely used in low voltage CT applications to monitor and control electrical systems effectively. The solid core design ensures consistent performance in demanding industrial and utility environments. Design Philosophy Our solid core current transformers prioritize precision, durability, and safety. Built with high-permeability magnetic materials and engineered winding configurations, they offer exceptional accuracy classes such as 0.5 for metering and 5P10/10P for protection class CTs. The design emphasizes minimal magnetic losses and stable thermal performance, […]